TL3B05 Force Sensor
Higher sensitivity model (Fz: + 500N) than the TL3B04. Larger allowable moment and larger distance between the force point and the action point compared with other 3-axis sensors.
Specifications
| Model | TL3B05-500N | |
|---|---|---|
| Rated capacity | Fx・Fy | ±500N |
| Fz | +500N | |
| Rated output | Fx・Fy | Approx. ±0.8 mV/V (±1600με) |
| Fz | Approx. ±0.2 mV/V (±400με) | |
| Allowable overload | 150% | |
| Non-linearity | ±1.0% RO (after interference correction) | |
| Hysteresis | ±1.0% RO (after interference correction) | |
| Interference | ±1.0% RO (after interference correction) | |
| Guaranteed temperature range | 10 to 60℃ (No condensation) | |
| Allowable temperature range | -10 to 70℃ (No condensation) | |
| Temperature effect on zero |
Fx・Fy | ±0.02% RO/℃ |
| Fz | ±0.08% RO/℃ | |
| Temperature effect on output |
Fx・Fy | ±0.02% RO/℃ |
| Fz | ±0.08% RO/℃ | |
| Recommended applied voltage | 1 to 5V AC or DC | |
| Allowable applied voltage | 10V AC or DC | |
| Input resistance | All | 140Ω ± 3% |
| Output resistance | Fx・Fy | 350Ω ± 3% |
| Fz | 700Ω ± 3% | |
| Initial imbalance | ±1.5mV/V (±3000με) | |
| Insulation resistance | 1000 MΩ 50V DC or more | |
| Cable | 8-core shielded cable (3m) Connector: ・For DSA-03A: 12-pin connector (-C) ・For DPA-03A/HDL-30A: 8-pin MD connector (-A) |
|
| External dimensions & weight | Φ42×H45(mm) 60g (excl. cable) | |
External Dimension